35 kV Cable Terminations

35 kV-Class Cable Terminations

A 35 kV-class cable termination design starts with the cable and the available compartment—not with a generic equipment label. We manufacture new equipment and supply new retrofit components to project specifications for customers in Texas and nationwide. For a useful quotation, identify the cable construction, conductor size, number of cables per phase, termination type, and the physical space available. Engineering, component availability, applicable standards, and lead time are confirmed for each project.

UL 891 switchboardsMADE IN USAFAST lead times
NEW EQUIPMENT. PROJECT FOCUSED.SERVING TEXAS
Electrical distribution cabinets arranged in a workshop

NEW SWITCHGEAR FOR YOUR PROJECT

MANUFACTURING / EQUIPMENT / TEXAS

Scope the cable compartment before selecting terminations

Compartment dimensions determine whether the specified cable and termination can be installed with the required working clearances and access. Provide the usable height, width, and depth, including barriers, buswork, support brackets, doors, and any obstructions. Clarify whether dimensions describe the entire compartment or the space available after internal components are accounted for. Drawings and photographs can help resolve uncertainties, but verified dimensions should govern design review.

Also identify how cables enter the enclosure, where they must land, and whether the termination will be accessible for inspection after assembly. Bottom, top, or side entry can affect cable routing and support locations. Tell us whether the design has fixed or removable barriers and how cables are restrained. These details help determine whether the requested arrangement is physically workable before equipment configuration and pricing are finalized.

Specify cable construction, size, and quantity

For each circuit, provide the cable manufacturer or construction where known, conductor material, conductor size, insulation type, insulation diameter, shield or concentric neutral arrangement, and overall cable diameter. The conductor size alone does not establish termination fit: insulation dimensions and shielding details can change the required accessory and available bending space. Include the cable voltage class and project requirements for the termination interface so the proposed configuration can be reviewed against the actual cable.

State the number of cables per phase and the number of circuits, along with whether conductors are parallel. Identify phase arrangement and any neutral or grounding conductors that must enter the compartment. For parallel cables, account for the combined space, separation, supports, and landing arrangement rather than describing only one cable. If cable data is preliminary, mark it as such; changing construction, quantity, or dimensions after design review can require a revised layout and quotation.

Coordinate termination type and stress control

Cable terminations manage the transition from the cable’s insulated and shielded construction to the equipment connection. Identify the termination type required by the project and the cable system, such as an appropriate indoor termination arrangement, and provide any specified interface or accessory requirements. Selection depends on cable construction, insulation dimensions, conductor, operating environment, and equipment geometry. Do not assume that an accessory suited to one cable design will fit another cable with the same nominal conductor size.

Stress-control components are part of the termination system and must be coordinated with the cable’s insulation and shield preparation requirements. Provide the applicable cable and accessory documentation when available, and identify any project-mandated components or approved product constraints. We review the requested arrangement as part of equipment scoping; the final accessory selection and compatibility should be confirmed for the specific cable. Field preparation and installation belong to qualified personnel following approved manufacturer procedures.

Reserve cable bend radius and support space

Cable routing must respect the minimum bend radius specified for the actual cable, including the conditions under which that radius applies. Share the cable manufacturer’s bend-radius requirements and intended approach to the termination. Consider the path from the enclosure entry through supports and into the connector: a compartment can appear large enough on paper yet leave insufficient room for a compliant bend once barriers, adjacent phases, and termination bodies are included.

Ask the design team to show the cable path and support points on a compartment drawing, rather than relying only on a straight-line landing dimension. Confirm whether the cable’s weight will be supported independently of the termination and whether the proposed cleats or brackets fit the enclosure layout. Account for installation access and the sequence for routing each cable. Any proposed change to entry location or support geometry should be reviewed before equipment release.

Define grounding and shield-bonding details

Describe how cable shields, concentric neutrals, metallic sheaths, and grounding conductors are to be handled at the equipment. The grounding arrangement depends on the cable design and project grounding scheme, so distinguish the required bonding points from conductors that simply pass through the compartment. Provide available grounding drawings or specifications, and identify any requirements for shield bonding, grounding leads, or connection locations that affect termination layout.

Coordinate grounding space with cable support and phase arrangement. Grounding conductors need a defined route and connection point that does not obstruct cable installation or interfere with barriers and adjacent equipment. Identify whether grounding connections are required within each cable compartment and how they relate to the project’s grounding design. Final grounding design and installation must be reviewed and performed by qualified personnel under approved project procedures; do not infer a bonding method from compartment appearance alone.

Check phase clearances and document the configuration

Phase-to-phase and phase-to-ground clearances must be evaluated for the actual termination geometry, cable position, barriers, and enclosure arrangement. Provide the requested phase sequence and orientation, and flag any project clearance criteria or insulation coordination requirements. Multiple cables per phase, large termination bodies, or constrained entry paths can affect spacing. Clearance review should use the proposed installed arrangement, not just nominal compartment dimensions, and should include grounded metal surfaces and internal barriers.

For quotation and engineering review, assemble the cable data, compartment and entry dimensions, termination requirements, grounding details, layout drawings, and applicable project standards. Identify whether this is new equipment or a request for new retrofit components, and provide the existing equipment configuration when components must interface with installed gear. We can review the scope and confirm availability, engineering, lead time, and documentation for the quoted configuration. Applicable standards and any listing status should be verified for that specific assembly; 35 kV-class equipment is not covered by UL 891 as a blanket switchgear listing.