New Equipment Pricing

Request New Switchgear Pricing

Requesting pricing for new switchgear starts with enough project information to define the equipment, configuration, and delivery requirements. Switchgear Builders Texas manufactures new equipment to specification using American components and serves Texas from the United States, with shipping available nationwide. Send the available project documents and identify what is still undecided; we can review the scope and confirm engineering, component origin, lead time, and applicable documentation for the quoted configuration. We quote new equipment and new retrofit components only.

UL 891 switchboardsMADE IN USAFAST lead times
NEW EQUIPMENT. PROJECT FOCUSED.SERVING TEXAS
Electrical switchgear cabinets arranged on shipping pallets

NEW SWITCHGEAR FOR YOUR PROJECT

MANUFACTURING / EQUIPMENT / TEXAS

Start With the One-Line and Project Scope

For a useful pricing review, provide the latest electrical one-line diagram showing the intended arrangement, incoming and outgoing sources, bus connections, protective devices, and loads. Include a drawing revision or date so our review is tied to the correct design. If the one-line is preliminary, label it as such and note expected changes; an early budgetary discussion and a firm quotation may require different levels of design definition.

Add the project name or reference, application, and the equipment boundary you want priced. Clarify whether the request covers a complete switchboard or switchgear assembly, a defined section, or new retrofit components intended for existing equipment. For retrofit components, identify the existing equipment manufacturer and model when known, plus available drawings and interface details. Compatibility and scope must be reviewed rather than assumed.

Identify Ratings and Site Conditions

List the required system voltage, frequency, phase, main and branch device ratings, bus requirements, and available fault-current or withstand requirements when established by the project design. State the grounding arrangement and any specified enclosure type or environmental conditions. If a value is pending, mark it as an open item instead of substituting an assumed rating; these parameters can affect both the equipment configuration and the engineering needed to price it.

Share the applicable project specifications and any owner, engineer, or authority requirements that affect the assembly. Include standards, documentation, labeling, and testing requirements as written in the project documents, and flag any requirements that conflict or need clarification. UL 891 applies to switchboards; it is not a blanket listing for every switchgear type. Listing and applicable standards must be verified for the proposed configuration.

Set Quantities and Define What Is Included

State the quantity of complete assemblies, sections, and any separate new retrofit components. If the design has repeated lineups or alternate arrangements, distinguish the base quantity from options or alternates. Provide an equipment schedule, section elevation, or marked-up drawing when available. Clear quantities help separate the cost of the defined scope from optional equipment and reduce uncertainty when project documents show more than one possible configuration.

Describe the intended supply boundary. Note whether the request includes only the manufactured equipment or also calls for drawings, specified accessories, documentation, or other deliverables. Identify items supplied by others and any interfaces that the equipment must accommodate. Pricing is for new equipment and new retrofit components manufactured or supplied to the reviewed specification.

Describe Options and Component Requirements

List requested options by function and, where possible, cite the specification or drawing that defines them. Examples may include metering, protective relaying, communications interfaces, control power, special compartment arrangements, or accessory provisions. Identify the required features separately from preferences and alternates. If the project team is evaluating choices, describe the decision criteria so the quotation review can distinguish a required configuration from a potential design alternative.

Specify American components as a project requirement when needed, and identify any component-origin documentation your procurement process expects. Origin, availability, engineering, and supporting documentation must be confirmed for each quotation; a component preference is not independent verification of domestic content or certification of Buy American or BAA compliance. Provide approved makes or functional requirements only when the project documents call for them, and identify where substitutions require prior approval.

Provide the Delivery Destination and Schedule

Include the complete delivery destination, including city, state, ZIP code, and any site or receiving constraints that could affect shipment planning. Note whether the location is a project site, warehouse, or another receiving point, along with delivery access, receiving hours, appointment requirements, or special handling instructions. We serve Texas from the United States and ship nationwide; the destination is needed to review the logistics associated with the specific quotation.

Give the required on-site date, requested shipment window, or milestone dates, and identify which date is contractual versus preferred. Include the project schedule context, such as construction sequencing or when approved drawings are needed. Lead time depends on the reviewed design, component availability, approvals, and project requirements, so it must be confirmed for each quotation. Do not treat a requested date as a delivery commitment until the quotation confirms the schedule.

Prepare Documents and Review the Quotation

A focused request package can include the one-line, equipment schedule, technical specification, relevant site requirements, and marked-up drawings, along with a contact for technical clarifications. Identify document status and revision, list unresolved decisions, and explain any assumptions the project team wants considered. If files are not yet available, send the known ratings, quantities, destination, and schedule first, then clarify what information will follow and when.

When reviewing pricing, compare the quoted scope and assumptions against the project documents, including quantities, ratings, options, component requirements, delivery basis, and exclusions. Ask about engineering items, lead time, component origin, and test or compliance documentation that need confirmation before purchase. Resolve deviations and open technical points before approval. Installation, servicing, testing, and energization require qualified personnel working under approved procedures; they are not substitutes for a complete equipment scope.

LET'S BUILD SOMETHING

Start with
the details.

Tell us what you’re working on. The more you can share about your project, the better we can begin the conversation.

PROJECT INQUIRY

Request a quote

This form opens your default email application. Your inquiry is sent only when you send the email. You can also email us directly or call our team.

* Required fields