Retrofit Manufacturing

Switchgear Retrofit Manufacturing

Switchgear retrofit manufacturing starts with the existing lineup, but the equipment supplied is new. We manufacture new replacement components or sections to project specifications, using recorded field dimensions, electrical ratings, connection details, and operating constraints to guide engineering. For projects in Texas and nationwide, a quotation review should establish what is being replaced, how the new equipment interfaces with retained gear, and what site information is still needed before design proceeds.

UL 891 switchboardsMADE IN USAFAST lead times
NEW EQUIPMENT. PROJECT FOCUSED.SERVING TEXAS
Electrical switchgear lineup in an equipment room

NEW SWITCHGEAR FOR YOUR PROJECT

MANUFACTURING / EQUIPMENT / TEXAS

Measure the Existing Lineup Before Design

Begin with an accurate record of the lineup as installed, not just the original drawings. Capture overall width, height, and depth; section boundaries; mounting and anchoring points; barriers; door and cover clearances; cable entry locations; and the positions of bus, supports, and control compartments. Note whether dimensions are measured from finished floor, enclosure edges, or another fixed reference. Photographs with scale references can help clarify features that a drawing omits.

Record the equipment nameplate information and identify the exact section or components proposed for replacement. Existing documentation may not reflect field modifications, so compare drawings, photographs, and measurements rather than assuming they agree. Flag inaccessible areas, uncertain dimensions, and obstructions for verification. These records help determine whether a new section can fit the available space and where additional field investigation is necessary before manufacturing details are finalized.

Document Ratings and Electrical Duty

Provide the system voltage, continuous current requirements, frequency, available fault-current information, and the protective-device details relevant to the replacement scope. Identify the main, feeder, or tie function and describe how the proposed section relates to upstream and downstream equipment. If the project has a required short-circuit rating, state its basis and provide the supporting system information available to the design team. Ratings must be reviewed together; a nameplate value alone may not describe the complete application.

Clarify which existing ratings must be maintained and which project requirements have changed. A replacement section may affect bus arrangements, protective devices, grounding, compartment separation, or coordination with adjacent gear. Provide the applicable one-line diagram, load information, protection requirements, and any owner or engineer criteria. Each quotation and configuration requires project review; no particular rating, availability, or design suitability should be assumed before those details are evaluated.

Verify Bus, Cable, and Control Interfaces

A retrofit depends on more than matching the enclosure outline. Document bus material and cross-section where known, phase arrangement, elevation, orientation, joint locations, and connection clearances. For cable interfaces, record conductor entry direction, landing space, lug or termination requirements, and the bend space available under the project design. Note grounding-bus locations and bonding paths, along with barriers or segregation requirements that affect access and compartment layout.

Describe control and auxiliary interfaces in the same detail: terminal locations, control voltage, wiring entry, interlocks, metering, communications, and signals that must connect to retained equipment. Provide schematics, wiring diagrams, and terminal schedules when available, and identify which devices or circuits remain in service. Compatibility is assessed for the specified configuration, not inferred from a manufacturer name or visual resemblance. Interface assumptions should be written down and resolved before fabrication.

Choose the Replacement Scope and Configuration

Define whether the project requires a complete new section, a new compartment or assembly, or particular new components engineered for the existing lineup interface. State what equipment will be removed, what will remain, and which boundaries are included in the manufacturer’s scope. This distinction supports a clearer engineering review and helps prevent missing items such as transition connections, enclosure extensions, mounting provisions, or control wiring at the boundary between new and retained equipment.

Where the original manufacturer’s drawings or component references are unavailable, provide photographs, measured sketches, nameplate details, and any maintenance records that identify the installed arrangement. Describe the operating function and required access rather than relying on a part number alone. We manufacture and supply new equipment and new retrofit components. Configuration, component origin, and applicable standards are confirmed during project quotation and review.

Plan Around Outage and Site Constraints

The outage window can shape the physical design and the sequence of work. Share the target shutdown period, permitted access hours, site rules, equipment-room restrictions, and the time available for removal, placement, connections, inspection, and owner acceptance. Identify whether temporary power, staged delivery, lifting access, narrow corridors, floor loading, or restricted door openings affect the replacement plan. These conditions should be considered early because they can influence section dimensions, shipping configuration, and installation coordination.

Distinguish manufacturing and delivery milestones from site installation and commissioning activities. The project team should identify who is responsible for field measurements, removal, rigging, connections, testing, and authorization to energize. Lead time is subject to review of the configuration, component requirements, and project documentation; it should be confirmed for each quotation rather than presumed. Installation, servicing, testing, and energization require qualified personnel working under approved procedures.

Assemble a Reviewable Submittal Package

A useful request for pricing includes a current one-line diagram, lineup elevations or general arrangement drawings, available nameplate photographs, field measurements, control schematics, and the specified electrical ratings. Add project specifications, applicable owner standards, connection details, and a clear list of retained versus replaced equipment. Mark information that is preliminary, measured in the field, or still awaiting confirmation. This allows engineering and purchasing teams to identify gaps before a proposed configuration is treated as final.

Ask the quotation and submittal process to identify the proposed scope, interface assumptions, required customer confirmations, and documentation available for the selected design. State any requirement for American components; component origin and supporting documentation must be reviewed for the particular configuration and should not be treated as independent verification of domestic-content compliance. For switchboard assemblies, UL 891 may apply, but listing and applicable standards must be verified for the specific configuration rather than assumed for all switchgear.

LET'S BUILD SOMETHING

Start with
the details.

Tell us what you’re working on. The more you can share about your project, the better we can begin the conversation.

PROJECT INQUIRY

Request a quote

This form opens your default email application. Your inquiry is sent only when you send the email. You can also email us directly or call our team.

* Required fields

Request a quote