Electrical Panelboards

Electrical Panelboards

Switchgear Builders Texas manufactures new electrical panelboards and supplies new retrofit components for projects in Texas and nationwide. A panelboard distributes power from a main device to branch circuits, so selecting one starts with the connected loads, incoming feeder, system voltage and phase, and the installation environment. We build to project specification using American components as requested. Configuration, component origin, applicable standards, documentation, and lead time are confirmed during quotation review.

UL 891 switchboardsMADE IN USAFAST lead times
NEW EQUIPMENT. PROJECT FOCUSED.SERVING TEXAS
Electrical switchgear cabinet and control panel

NEW SWITCHGEAR FOR YOUR PROJECT

MANUFACTURING / EQUIPMENT / TEXAS

Plan branch-circuit distribution around the loads

A panelboard organizes outgoing branch circuits for lighting, receptacles, equipment, or other designated loads. Begin by identifying what each circuit will serve, its expected load, and whether it is continuous, intermittent, or subject to a specific operating cycle. Include known future loads rather than relying on an assumed spare capacity; the engineer can then determine circuit count and capacity in the context of the complete system design.

For each branch circuit, provide the required overcurrent-device type and rating, pole count, and any special operating or coordination requirements established by the project. Note circuits with dedicated equipment, shared-neutral considerations, ground-fault protection, or other specified protection needs. These details help define a workable panelboard arrangement, but final selections must be coordinated with the design documents and applicable code requirements.

Choose the main and define the incoming feeder

The main device establishes how the panelboard is connected to and isolated from its supply. Specify whether the design calls for a main breaker, main lugs, or another defined arrangement, along with the required device rating and configuration. The choice depends on the upstream distribution design, available protection, service or feeder role, and project requirements; it should not be inferred from a panel name or an existing cabinet alone.

Describe the incoming feeder with its source and destination, conductor material if specified, number of conductors, grounding arrangement, and the design parameters needed to coordinate the connection. Identify any required terminal provisions and available space constraints. Confirm that the proposed main and panelboard configuration fit the upstream protective scheme and the downstream load plan. Supply relevant one-line diagrams and specifications so the quotation review can identify open design questions.

Match voltage and phase to the system

State the system voltage and phase explicitly, including the conductor arrangement where it affects the panelboard configuration. Identify whether the panel serves a single-phase or three-phase distribution system and provide the intended line-to-line and, where applicable, line-to-neutral voltage. Do not assume that a familiar voltage or phase is available or suitable: project parameters require review against the specified design and equipment configuration.

Also identify the electrical characteristics that affect selection, such as the system grounding method and the required short-circuit or withstand parameters established by the engineer. If the panelboard connects to transformers, generators, or other alternate sources, document the intended arrangement and any transfer or interlocking requirements in the project scope. Availability and engineering compatibility are confirmed for each quotation rather than assumed from a nominal voltage description.

Specify the enclosure for its installation environment

Enclosure selection should reflect where the panelboard will be installed and the conditions it must withstand. Provide the intended location, whether indoors or outdoors, exposure to moisture or dust, and any corrosive, washdown, or temperature conditions identified by the project. State the required enclosure rating or governing project specification. A general description such as “weatherproof” is not enough to establish a suitable configuration.

Include mounting orientation, available wall or floor space, access and working-clearance constraints, and the direction from which feeder and branch-circuit conductors must enter or leave. Identify room layouts, cabinet dimensions, and any restrictions on door swing or service access. These inputs can affect enclosure dimensions and wiring arrangement. Installation, servicing, testing, and energization must be performed by qualified personnel under approved procedures.

Prepare a complete panel schedule and submittal package

A useful panel schedule identifies circuit numbers, descriptions, connected equipment, poles, specified breaker ratings, and load information required by the design. Include phase assignments where applicable, spare or space designations, and any project conventions for naming and circuit descriptions. Mark incomplete or provisional loads clearly. This lets the panelboard configuration be reviewed against the intended distribution instead of filling gaps with unverified assumptions.

For quotation and engineering review, provide the schedule alongside the one-line diagram, panel location, upstream source details, enclosure requirements, and applicable project specifications. Note requested submittals, such as layout information or device data, and state which standards or listing requirements apply to the configuration. UL 891 is a switchboard standard, not a blanket standard for panelboards; verify applicable standards and any required listing for the particular assembly.

Scope new panelboards and retrofit components

This offering is for new equipment and new retrofit components. For a new panelboard, define the complete intended assembly and its interfaces with the existing or planned distribution system. For a retrofit, identify the existing panelboard manufacturer and model, component descriptions and markings, dimensions, connection details, and available drawings. Photographs of equipment identification and the installation can support review, but they do not replace verified electrical and mechanical data.

Compatibility must be assessed rather than inferred from appearance or a catalog description. Provide the reason for the retrofit, the component being replaced, relevant circuit and main-device details, and any known changes to the original system. We review the supplied information to determine whether the requested new component can be specified for the application. Ask for pricing with the project documents; availability, engineering, component origin, documentation, and lead time are confirmed for each quotation.

LET'S BUILD SOMETHING

Start with
the details.

Tell us what you’re working on. The more you can share about your project, the better we can begin the conversation.

PROJECT INQUIRY

Request a quote

This form opens your default email application. Your inquiry is sent only when you send the email. You can also email us directly or call our team.

* Required fields